Back to dashboardAlarm Codes
Back to dashboardGood intent calls
- 609Other manually initiated good intent call
- 611Wrong location
- 612Vicinity alarm Incident at another location, including multiple calls from different locations for the same fire.
- 621Smoke scare or smell of smoke
- 622Steam, vapour, fog or dust mistaken for smoke
- 624Authorised burn under control
- 625Barbecue
- 626Burglar alarm ringing
- 628Bomb scare, no bomb found Includes a parcel that resembles a bomb.
Malicious false alarm
- 711Malicious false alarm
System malfunctions Alarm signalling equipment (ASE) on site
- 702Alarm triggered by extreme weather
- 734Sprinkler malfunction Includes pressure fluctuations and equipment faults.
- 735Smoke detector malfunction Continuous or intermittent fault.
- 736Heat detector malfunction Continuous or intermittent fault.
- 737Fire indicator panel (FIP) showing normal on arrival
Panel reset and Entry Advice
Try to establish why the panel is showing normal and record the findings on the Entry Advice. If a reset prevents you from locating the detector, the officer in charge may decide a site search is needed to ensure the premises are safe.
- Fully monitored
- Only fire service personnel can reset the panel.
- Local system, no ASE
- The owner or occupier may reset after a thorough investigation of the area finds no cause for the alarm.
- Partly monitored
- If the monitored part triggered the alarm (ASE alarm light on), only fire service personnel can reset. If the local-only part triggered it (ASE alarm light off), the owner or occupier may reset after a thorough investigation of the area finds no cause for the alarm.
Victorian law restricts resetting a panel after it detects a fire or a simulated fire condition and sounds an alarm. Fire service consent or a reasonable excuse is required under the applicable provision.
FRV guidance on false alarms and panel resets - 738Suspected alarm system fault Panel, wiring, ASE or inadequate maintenance.
- 739Other system malfunction
Local system malfunctions No ASE on site
- 741Local sprinkler malfunction
- 742Local or domestic smoke detector malfunction
- 743Local heat detector malfunction
Private security monitoring
- 745False alarm at residential premises
- 746False alarm at commercial premises
Alarms without a malfunction
- 751Smoke detector operated, no fire A working detector sensed a simulated fire condition or a condition that did not warrant an alarm. Detector type or placement can contribute.
- 752Heat detector operated, no fire A working detector sensed a simulated fire condition or a condition that did not warrant an alarm. Detector type or placement can contribute.
- 756Cooking fumes Includes toast and other food.
- 762Accidental alarm activation Human activity triggered the alarm, including damage to a sprinkler head.
- 763Alarm test carried out without notification
- 764Service company carried out an incorrect test
- 769Other unintentional alarm
Code reference from FRV’s P377 False Alarm Codes pocket card (January 2021).
FRV Alarm Assessment & Engagement
Quick Reference
Back to dashboardGARS
Back to Quick ReferenceGreater Alarm Response System · FRV P387 · March 2022. Check the current FRV response matrix for operational use.
Grass and scrub notes from P387
- The Incident Controller can request FRV pumpers for asset protection and consider a formed or ad hoc strike team.
- Include the co-located CFA station’s tanker at 1st alarm when the fire is in that co-located station’s primary area.
- Allow one CFA Forward Command Vehicle (FCV) with a strike team leader for every five CFA tankers. Tankers can be dispatched individually or in pre-formed strike teams.
- The initial Incident Controller decides whether to transfer control to an Incident Control Centre (ICC). The card refers to discussion with the Regional Controller and ICC-based Incident Controller under JSOP 3.15.
- Beyond 5th alarm, the mix of FRV and other agency resources depends on need and complexity.
- Options include slip-ons, big fills, quick fills, bulk water tankers, ground observers, RPAS and air support.
- The 2022 card describes aircraft being dispatched if available under Predetermined Dispatch in designated areas at Fire Danger Index 12 or higher. It also lists requests via Firecom (FSCC) from the fireground or via the State Air Desk from a Commander or above. Check current dispatch criteria.
General notes from P387
- The Incident Controller can request specific appliances, equipment or personnel, including additional command staff.
- Respond a Senior Station Officer at 2nd alarm and above.
- Beyond 5th alarm, the card specifies four additional primary appliances per alarm for structure and non-structure fires. For other incident types, except grass and scrub, it lists two additional FRV primary appliances per alarm.
- In the Melbourne CBD, the standard initial response to structure fire exchange calls is at least three primary appliances. The card also specifies at least three for automatic alarms, from heavy rescue to full sprinkler calls.
- Enhanced responses can increase appliance numbers.